    CW fNIRS with short channel regression and amplitude modulation

    Thumbnail
    Abstract
    Functional Near Infrared Spectroscopy (fNIRS) is a relatively new and promising field within brain imaging and neuroscience. It offers a cost efficient, non-invasive method for brain studies, both for research and clinical purposes. Based on existing NIRS technologies, fNIRS uses near infrared light to measure the presence of different chromophores in the brain. Recent studies have explored the possibility of using data from a short separation channel as a basis for regression filtering to remove noise generated by the superficial layers of the head, but faces a challenge as the short channel quickly saturates. This report describes the process of making a working fNIRS instrument with both a short- and a long-channel, which measures changes in the amount of hemoglobin in the brain during cognitive tasks. It does so by detecting the attenuation of NIR light travelling from the emission source, through the brain and to a detector. The goal is to overcome short channel saturation challenges by using an amplitude modulated signal. The technology of NIRS and fNIRS is accounted for, as well as theory related to light and its behavior in human tissue. The modified Beer-Lambert law, which must be applied to continuous wave (CW) fNIRS data to calculate the relative concentration of chromophores in the blood, is explained. The anatomy of the skin and the human brain is accounted for, as well as physiological processes related to neural activity in the brain. The circuit design of the instrument is thoroughly explained, as efforts have been made to overcome the hardware challenges posed by implementing a short distance (1 cm) between light source and detector. Instrument design and functionality was tested by performing blood flow restriction tests and cognitive tests on several subjects. The data was read and pre-processed in a graphical user interface programmed in MATLAB. Final data analyses were compared to earlier studies and showed that the instrument works as expected. The fNIRS instrument described in this report is meant to accommodate the need for precise, low-noise measurements of hemodynamic responses in the brain, and facilitate further research of short-channel regression filtering in fNIRS.
    URI
    http://hdl.handle.net/20.500.12199/2924
    Collections
    • TKD - Department of Mechanical, Electronics and Chemical Engineering [8]
    Date
    2018-05-23
    Author
    Engvik, Max
    Gjestemoen, Marte Helén Andersen
    Horpestad, Anders
    Martinsen, Janne
    Nordli, Stian
    Show full item record
    Engvik_Max.pdf (3.366Mb)

    Copyright © 2020 Oslo and Akershus University College of Applied Sciences
    Contact Us | Send Feedback
    Powered by KnowledgeArc
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    Copyright © 2020 Oslo and Akershus University College of Applied Sciences
    Contact Us | Send Feedback
    Powered by KnowledgeArc